Afinion error codes
Web•The Afinion™ HbA1c Test Cartridge must reach an operating temperature of 18-30°C (64-86°F) before use.Upon removal from refrigerated storage,leave the Test Cartridge in the … WebThe Afinion™ ACR (albumin, creatinine and albumin/creatinine ratio) detects microalbuminuria in human urine. Microalbuminuria is the first clinical sign of diabetic renal disease and cardiovascular disease. Simple testing for microalbuminuria is extremely efficient as an early indicator of renal failure. Short assay time in 5 minutes
Afinion error codes
Did you know?
WebThe reagents may only be used on the Afinion AS100 Analyzer. I. Device Description: Afinion AS100 Analyzer The Afinion™ test system is a closed system consisting of the Afinion™ AS100 Analyzer and the Afinion™ Test Cartridges. The AS100 is a multi-assay analyzer for point-of-care use. WebAfinion™ HbA1c Control contains liquid preparations of Stabilized Porcine Whole Blood (Control CI) and Human Whole Blood (Control CII). Designed for use with the Afinion™ …
WebJul 17, 2024 · Information Codes and Troubleshooting When an information code appears 24 Information codes caused by test-specific limitations 24 ... Afinion 2 System, consisting of the Afinion 2 Analyzer and the Afinion Test Cartridges, is for in vitro diagnostic use only. Afinion 2 Analyzer is a compact multi-assay analyzer for WebTroubleshooting –Most Frequently Observed Error Codes (See SOP for Full List) Error Code Description Troubleshooting 103, 104 Hemoglobin concentration is below or above …
WebInformation Codes and Troubleshooting When an information code appears Information codes that might appear during use of the Afinion 2 Analyzer refer to specific information … WebNov 1, 2024 · Assay Specific Information Codes Code Cause 107 Creatine too high 108 Blood in the urine detected by the Analyzer* * see Afinion ACR Package Insert Getting Started Take time to familiarize yourself with the Analyzer and the test kit. AFINION™ ACR Test Cartridge Sampling device Barcode Capillary ID area 1 Symbol Cause/Explanation
WebSep 29, 2024 · Afinion Hba1C Error Code 208 0 Afinion Hba1C Error Code 208. Cartucho de análisis previamente utilizado. Repeat the test with a new sample afinion a1c error codes results for websites listing. The control lot has passed expiration date. Diabetes c, complications trial research g, nathan dm, et al. What Does this Error Code Mean?
heartship malluskWebThe Afinion™ 2 Analyzer is a compact, rapid, multi-assay analyzer that provides valuable near patient testing at the point-of-care. With the Afinion™ System ... mouse logitech g500WebThe Alere Afinion™ AS100 Analyzer is a compact rapid, multi-assay analyzer that provides valuable near patient testing at the point-of-care. It utilizes the latest technology and provides a simple, fast and reliable method by which to … mouse logitech g502 hero altexWebAug 3, 2024 · Contact your local Alere Afinion™ supplier for assistance. Self-test error. Analyzer in non- operative mode Analyzer failure Restart analyzer. If the problem … heartship allianceWebThe probable explanation was that the detection systems causing the error codes were too sensitive. Regardless of cause, the frequency of error codes was assessed as too high. Conclusion Afinion was easy to handle. The precision of … heartshine pageanthttp://nwprimarycare.com/Staff%20Training%20Info/Afinion%20AS100%20Analyzer%20User%20Manual%20US.pdf heartship cicWebClick on each step below to reveal the instructions and get started. The Afinion Analyzer at a glance How to operate the analyzer Step 1: Getting started Step 2: How to switch on … mouse logitech g pro x superlight kabum